Our
GRYPHON ®
2 is a hardware adapter that provides remote
connectivity for multiplexed automation and automotive communication
networks. GRYPHON
® 2 doesn’t
require any programming and is ready to run out-of-the-box as a
stand-alone product. It uses an Ethernet connection to provide a
high-speed user interface. Users can interface to the
GRYPHON
® 2 by
either using Dearborn Group’s Hercules high performance analyzer or
writing their own applications using the provided C++ libraries.
The
GRYPHON ®
2 has three expansion slots that lets you
install numerous optional Plug-In Modules designed to support specific
protocols. The benefit of this capability includes the ability to support
multi-client connection (e.g., running two client connections – one
Hercules application and one user-written test application).
Supported Protocols: CAN (canbus), GMLAN,
GMUART, Honda, ISO9141-2, ISO11898 (CAN), ISO11992, ISO15765, J1850 GM
(Class 2), J1850 Ford (SCP), J1850 DCX, J1939, J1962, J2284, J2411 (GM
SW), J2534, KWP2000 (ISO14230), LIN, SWCAN, UBP.
The part number for each Plug-In Module option is
DG-GRYPH-MOD-X (where the ‘X’ represents an alphabetic letter of a
specific Plug-In Module.) Refer to the
Gryphon 2® Data Sheet for a list of modules that are supported. Also
see
Gryphon 2® / S-CAT Modules data sheet.
Note: You must also order at least one
Plug-In Module for your GRYPHON
® 2
to communicate using the protocol of the selected Plug-In Module.
Common Applications
Application
|
Description
|
Monitoring
Analysis
Diagnosis |
GRYPHON(hardware
adapter)
is also used as an interface for our
Hercules CAN Analyzer software
tool. Hercules is our high performance Windows analyzer software
with protocol support for CAN (canbus), GMLAN, ISO11898 (CAN),
ISO15765, J1850 GM (Class 2), J1850 Ford (SCP), J1850 DCX, J1939,
J1979, J2284, J2411 (GM SW), LIN and SWCAN. |
PV / DV
Interface
Analysis
Diagnosis |
Included in test stand
applications. |
Available Accessories and Options
The following items are available.
Part Number
|
Product Name
|
MP-HERC
|
Hercules high performance
Windows analyzer software for CAN, J1850 and LIN. |
MP-GRYPH-LV
|
GRYPHON
(hardware
adapter) Labview Toolkit.
|
MP-PT-SOFT
|
Embedded pass-through
software that translates between two modules. |
MP-ETHERNET-PCCARD
|
Ethernet PCMCIA card for
your PC. Lets you conveniently add an Ethernet interface.
|
MP-OBDII-O-CABLE
|
6-foot open-ended OBDII
cable. |
MP-ETHERNET-X-CABLE
|
Available in either
straight-through (S) or crossed (C). |
MP-OBDII-DB15-CABLE
|
Custom J1962 cable for connection to
GRYPHON
(hardware
adapter)
shared module connector.
|
MP-INTERFACE-CABLE
|
6-inch OBDII cable with
DB9 male connector. |
MP-OBDII-EMC-CABLE
|
6-inch J1962 cable for connection to
GRYPHON(hardware
adapter)
shared module connector. |
MP-OBDII-BOX
|
An OBDII box that gives
you a practical and easy way to establish in-line electrical
connection to the Vehicle On-Board Diagnostic connector.
|
Related Product
Part Number
|
Product Name
|
MP-GRYPH-FO |
Gryphon
Fiber Optic – a Fiber Optic hardware
adapter that supports communication with in-vehicle networks via an
unobstrusive fiber-optic connection.
|
MP-GRYPH-S3
|
Super CAN Analysis Tool 3
(S3) – This approved GMLAN CAN analyzer solution bundles our next
generation S-CAT hardware and Hercules software package to support
advanced communication with in-vehicle networks. It uses the CAN
(low-speed, mid-speed and high-speed) protocol, and lets you add
Class 2 and LIN protocols that are supported in software. It is
ideal for diagnostics, simulation and custom applications.
|
|
Software and
Device Drivers
Note: These
programs can be used with the Gryphon, S-CAT and S-CAT2 products.
Gryphon® C/C++ Libraries, Release 4.2
-
Win32 installer. – This file installs the Gryphon®
Libraries for use with C++, C and VB applications. (EXE, 2444K) released
09/14/05.
This release is for Win32 platforms only. It consists of the file "setup.exe",
which is a self-installer program. The self-installer contains: the
Release Notes document; the C and C++ libraries, including dynamic link
library files (.DLL), header files (.H), and link support files (.LIB);
user manuals (.PDF); sample application program source and project files;
and a Visual BASIC module file. To accommodate the use of Gryphon manifest
constants in application code, the latest header files for the Gryphon
protocol are also included in both packages.
See
Release Notes for details of functional changes in the
libraries.
Source code. – This file contains the source code for Gryphon
C/C++ Libraries for use with Unix (and other non-Win32) platforms, and
non-Microsoft C++ development environments. (tar.gz, 1832K) released
09/14/05.
Note: If using a browser on Windows, be sure the browser does not
add a ".tar" suffix to the archive file.
Unix source code Readme file. – For Unix source code users.
Missing DLL Help information. For customers who are unable to use the
Gryphon® C/C++ libraries (on Windows) due to "missing DLLs".
Gryphon®
EasyAPI Library
Gryphon®
Applications
Gryphon®
Monitor (GryphMON) - Version 1.92
– Used to monitor traffic on a Gryphon®.
This ZIP file also contains the GryphDB program. (ZIP, 4,032K).
GryphMON Manual – in html format.
GryphDB Manual – in html format. This product creates a database that
gets imported into GryphMon for message transmission.
GryphSpeeds - Version 1.20 – A utility program that allows the speed
entries in gdevs file to be edited remotely. (ZIP, 1,983K).
GryphLIN - Version 1.12 – Used to monitor LIN traffic on a Gryphon ®.
(ZIP, 2,222K).
GryphLIN Manual – in html format.
GryphLIN Sample LDF – Sample LIN definition file. Note: this is for
example purposes only, the required LDF will vary by implementation (LDF,
8K).
GM
DPS Users’ Resources – a collection of resources required to use the
GM DPS software.
Note: For previous software and driver
versions, see the
Archive Section of our Download page.
Product
Information
Product Data
Sheet
Product Manuals
Gryphon 2®
User Manual – Version 1.0 (PDF,
894K).
Gryphon®
Technical Information.
How to connect Fault Tolerant CAN networks v2.0 (PDF, 64K).
Gryphon®
C++ Class Library Manual – Version 4.2
(PDF, 2003K).
Gryphon®
C/Visual Basic Library Manual – Version 4.2
(PDF, 1884K).
Gryphon®
Module Pinouts.
Note: For previous manual versions, see
the
Archive Section of our Download page.
Examples
Display Gryphon®
Sample Code, Examples, Diagnosis Tips, Application Notes
|
|