Part No: MPSF-PB-Tools-T4
Physical Installation Quality and Protocol Analysis
Quick and Easy Testing of Bus Physics and Bus Communication
Features
Combines all in one device:
- Signal Tester
- Protocol Analyzer
- Storage Oscilloscope
Use Cases:
- Troubleshooting
- Preventive Maintenance
- Setup and Commissioning
- Documentation
- Acceptance Testing
- Optimization
- Laboratory Tests
Overview
Advantages:
- Time saving because it is easy to use and results are self-explanatory
- Cost saving, no expert knowledge necessary
Functions:
- Full bus testing without a Notebook and without operative PLC possible
- Bus-check possible during running operation
- Combines the diagnostic functions of previously separate tools in one device
- With a single mouse click (PC mode) or a single push of a button (stand-alone mode) a full examination of a PROFIBUS network is initiated
- The PC software provides many additional features for executing, analyzing, and managing bus tests.
- A status bar continually shows the current bus state
- Choice between quick test or user-controlled test
- The Topology Scan feature determines the overall cable length and the cable length between slaves
- Detailed test report
- The Long-Term Trend view is used for detecting sporadic faults
- In the oscilloscope and frame analyzer views, experts can perform in-depth detailed analysis
- For bus and device tests without operative PLC, only the baud rate needs to be specified – no configuration or parameterization is required.
Technical Data
Property |
Value |
Power Supply |
Via External AC Adapter 100 V .. 240 VAC 50/60 Hz (Galvanically Isolated) or Direct Connection to 24 VDC ±20%, Approx. 0.5 A (Without Galvanic Isolation) |
RS485 (DP) |
PROFIBUS D-Sub Connector, 9 Pins, Power Supply for External Bus Termination
Protocol and Frame Analysis:
PROFIBUS DP and DPV1, Automatic Baud Rate Detection 9.6 Kbit/s .. 12 Mbit/s
Signal Analysis:
PROFIBUS DP, DPV1, FMS and MPI; Signal Qality Index 0 .. 5000 Determined from Signal Waveform as well as Signal/Noise Ratio and Rise Time; Signal Sampling with 8/16 Samples per Bit
Oscillogram display:
Test Range: ±5V at 10mV Resolution (Differential), 0V...15V at 15mV Resolution (A or B to DGND); Sampling Rate: Up to 384MSamples/s; Sampled Points: 2,400 (Signal Details), 8,192 (Oscillogram Analysis)
Topology scan:
Active, Maximum Distance 230 m, Accuracy ±2 m |
USB |
V 2.0, High Speed 480 Mbit/s, Galvanically Isolated |
Trigger |
OUT: approx. 5 V, Active Low, Connection to Storage Oscilloscope |
Internal Memory Capacity |
10 Memory Locations for Quick Tests, 1 Trend Log, for 41 Days Maximum |
Dimensions |
HxWxD: 35mm x 170mm x 110mm |
Weight |
Test Tool, No Cable: Approximately 0.45kg; Complete Carrying Case: Approximately 3.9kg |
Ambient Conditions |
- Operating Temperature: 0 .. 50 °C, Storage Temperature: -20 .. 70 °C,
- Air Humidity: 10 .. 90% without Condensation
|
Conformity |
CE, FCC, VCCI |
Operation |
Via Four-Line Display and Four Function Keys or via PC/Notebook.
Display Localization: DE,EN,FR,IT,PL,ES (without National Language Specific Characters) |
PC Operating Software |
PROFIBUS Diagnostic Suite, see Separate Manual |
Order Information
BC-600-PB
- PROFIBUS Tester 4 "All-In-One" Test Tool for PROFIBUS DP Bus Physics and Communication
- Carrying Case
- Wide-Range Power Supply with
European and U.S. Power Cables
- Connection Cable for 24VDC Direct Power Supply
- "Standard" D-Sub PROFIBUS Adapter Cable
- USB Cable
- Terminal Block for Trigger Input/Output
- User Manual
- PB-DIAG-SUITE
PC Software on CD-ROM With Getting Started Manual
Accessories
BC-600-PB-CB-DSUB1
- RS485 D-Sub Adapter Cable for Testing of Live PROFIBUS Segments with Reduced Influence on their Operation
BC-600-PB-CB-M12
- D-Sub to M12 Adapter Set with T-Piece and M12 Bus Termination for PROFIBUS DP
PB-LSZ-CHB3
- Digital Fieldbus Leakage Current Clamp for Locating EMC Problems, 40 ..1000 Hz, MIN/MAX, Data Hold, Measuring Cables, supplied in a Handy Case (fits in Empty Compartment of Carrying Case)
BC-PBMB-PB-S
- D-Sub Service Interface with Active Bus Termination and 90° Angled Connector for PROFIBUS DP
BC-M12DP-PB
- M12 Service Interface for PROFIBUS DP, Comprising M12 T-Piece, End Cap and M12 Connection Cable (1 m)
|